Heat Recovery Water Heater

Heat Recovery Water Heater
The Shintaeki Heat Recovery Water Heater uses the surplus energy of air conditioning to produce free hot water, reducing the cost of running high-wattage water heaters. It can also cut air conditioning electricity costs by up to 10–20%, because heat from the air conditioner is released through the SHINTAEKI water heater, which reduces the heat load and lets the air conditioner cool more efficiently.
Fits Air Conditioners of Any Brand
Can be installed on split-type air conditioners from 9000 BTU upward, of any brand. Produces hot water up to 80 degrees without using electricity. Easy to install and maintain, and harmless to the air conditioner.
Heat Recovery Water Heater highlights
- Hot Water up to 80 °C Produces hot water from the surplus energy of the AC without using electricity
- Cut AC Power Costs by 10–20% Helps release heat from the AC so it cools more efficiently
- Split-Type AC from 9000 BTU Installs on split-type air conditioners of any brand
- No Electrical Leakage Issues Easy to install and maintain, and harmless to the air conditioner
- Homes
- Hotels
- Spas
- Resorts
- Beauty salons
- Hospitals
How the Heat Recovery Water Heater Works
The SHINTAEKI Heat Recovery Water Heater produces hot water from the surplus energy of air conditioning as follows

- The refrigerant circuit of the air conditioner is connected at the discharge line leaving the compressor, at about 80–90 degrees Celsius, to the hot water tank
- Heat from the refrigerant line transfers through a heat exchanger pipe inside the tank, raising the temperature of the water (up to 80 degrees Celsius)
- After exchanging heat, the refrigerant flows on to the air conditioning system to release heat through the condenser as normal
Digital temperature control box
Select operating times and control water temperature as needed
- 10–15 °CCool air from the AC after the refrigerant exchanges heat with the air
- 240–260 psiPressure at which the compressor compresses the refrigerant
- 70–90 °CTemperature of the refrigerant line exchanging heat with the water
- 60–80 °CHot water temperature supplied to the shower, tap and hand sink
Specifications
Shintaeki technical specification for model NWT — 150 / 200 / 300 litre tanks
| Model | Unit | NWT-150LE2 | NWT-200LE2 | NWT-300LE2 |
|---|---|---|---|---|
| Net dimensions (D × H) | mm | 560 × 1115 | 560 × 1305 | 600 × 1575 |
| Net weight | kg | 32 | 38 | 63 |
| Capacity | L | 150 | 200 | 300 |
| Operating water pressure | psi | 100 | ||
| Max. testing water pressure | psi | 150 | ||
| Max. testing refrigerant pressure | psi | 600 | ||
| Max. operating temperature | °C | 80 | ||
| Heat exchanger coil circuit | – | 2 | ||
| Heat exchanger coil material | – | Titanium | ||
| Inner tank material | – | Stainless Steel 316 | ||
| Inner tank thickness | mm | 1.5 | ||
| Insulation | – | Polyurethane | ||
| Outer tank material | – | Stainless Steel 304 | ||
| Water connection size | inch | 3/4" | ||
| Refrigerant connection size | inch | 1/2" | ||
| Electric heater (option) | W | 1500 / 3000 | ||
| Anti limescale | – | Magnesium Anode | ||
Data from the manufacturer's documents, subject to change without notice — ask about the right size for your use at 086-493-5886


Want Free Hot Water
from the AC You Already Have?
Tel 086-493-5886 , 089-497-9681
Tell us your AC size and hot water use, and our team will help you choose the right tank size