Heat Pump System

PROPOSAL HEATPUMP SYSTEM
Special Design Compressor for Heat Pump Water Heater
A compressor designed specifically for heat pump use
producing hot water up to 80 °C with excellent efficiency
Automatic Heat Pump Data Record
The Heat Pump sends its operating data over Wi-Fi, so you can be sure
our service team is looking after your unit at all times
Working Principle
Working principle — A heat pump draws heat from the air to make hot water, using electricity only to drive the compressor and fan

- The fan draws air through the evaporator and the refrigerant absorbs heat from the air
- The compressor raises the pressure and temperature of the refrigerant
- The hot refrigerant transfers heat to the water through the heat exchange tank, delivering hot water for use
- The refrigerant passes through the expansion valve to lower its pressure, then returns to absorb heat from the air again
Main Components
Heat pump main component — SHINTAEKI products are designed by engineers with more than 10 years of experience in Heat Pump systems for hotels and industrial plants
-
Compressor
Copeland & Panasonic
Quality compressors from Copeland and Panasonic
-
Heat Exchanger
Tube-in-Tube
Tube-in-tube heat exchanger with good heat transfer to the water
-
Electronic Expansion Valve
Electronic expansion valve controlling refrigerant flow
-
Screen-touch Display Board
Microcomputer intelligent control
Touch screen with intelligent microcomputer control
-
Copper-finned Heat Exchanger
L-STYLE blue hydrophilic fin
Blue corrosion-resistant coated fins, larger heat exchange area and inner-grooved copper tubes for high efficiency
Specifications
Air Source Heat Pump : SHINTAEKI — from 3.5 to 90 kW. Scroll the table to the right to see all models
| Model | Unit | SHIN-3.5W | SHIN-5.0W | SHIN-7.5W | SHIN-12.0W | SHIN-18.0W | SHIN-24.0W | SHIN-36.0W | SHIN-42.0W | SHIN-52.0W | SHIN-90.0W |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Heating Performance | |||||||||||
| Heating capacity | kW | 3.5 | 5.0 | 7.5 | 12.0 | 18.0 | 24.0 | 36.0 | 42.0 | 52.0 | 90.0 |
| Power input | kW | 0.833 | 1.19 | 1.79 | 2.86 | 4.29 | 5.7 | 4.6 × 2 | 5.6 × 2 | 7.0 × 2 | 12.9 × 2 |
| Running current | A | 3.8 | 5.45 | 8.20 | 13.00 | 6.55 | 8.7 | 7.0 × 2 | 8.5 × 2 | 13.0 × 2 | 19.8 × 2 |
| COP | – | 4.2 | 4.2 | 4.2 | 4.2 | 4.2 | 4.2 | 3.91 | 3.75 | 3.75 | 3.5 |
| Hot water production | L/h | 180 | 200 | 250 | 372 | 420 | 529 | 774 | 960 | 1484 | 1940 |
| General | |||||||||||
| Power supply | V/Ph/Hz | 220/1/50 | 380/3/50 | ||||||||
| Outlet water temp. | °C | 55 | |||||||||
| Rated / Max. outlet water temp. | °C | 60 | |||||||||
| Ambient temp. range | °C | −7 ~ 43 | |||||||||
| Rated pressure drop | kPa | 50 | |||||||||
| Controller | – | Micro processor based digital wire controller with LCD display | |||||||||
| Casing material | – | Stainless Steel 304 | |||||||||
| Components | |||||||||||
| Compressor type | – | Rotary | Scroll | ||||||||
| Refrigerant | – | R410a | |||||||||
| Material | – | Titanium | |||||||||
| Water heat exchanger | – | High efficiency tube-in-tube or coaxial | |||||||||
| Air side heat exchanger | Type | High efficiency copper tube (interior screw) nested in aluminium fin | |||||||||
| Water connection (inlet & outlet) | inch | 1" | 1-1/4" | 2" | 2" | 2-1/2" | 2" | ||||
| Coil type | – | Fin-tube: blue coated aluminium fins + inner | |||||||||
| Coil tube dia. | mm | 7 or 7.94 | |||||||||
| Coil rows | Nos. | 1 | |||||||||
| Operating Control | |||||||||||
| Type | – | Full-automatic, intelligence | |||||||||
| Control panel | – | LED display, back light | |||||||||
| Display | – | Water tank temp., Ambient temp., Time, Operating mode, Discharge temp., Coil temp., Error code | |||||||||
| Setting | – | Time, Time On/Off, Water tank temp., Defrosting cycle, Start temp. of defrosting, Exit temp. of defrosting, Exit cycle of defrosting, Power lost memory | |||||||||
| Defrosting | – | Automatic 4 way valve reverse | |||||||||
| Protection function | – | Compressor overload, discharge temp. and etc. | |||||||||
| Dimensions & Weight | |||||||||||
| Noise level | dB(A) | 43 | 48 | 52 | 54 | 55 | 56 | 58 | 65 | 60 | 70 |
| Dimensions (L × W × H) | mm | 930 × 360 × 550 | 930 × 360 × 550 | 930 × 360 × 550 | 720 × 720 × 820 | 720 × 720 × 1050 | 1185 × 430 × 1255 | 1405 × 800 × 1050 | 1405 × 800 × 1050 | 1498 × 798 × 1443 | 2000 × 1005 × 1975 |
| Net weight | kg | 40 | 65 | 75 | 90 | 125 | 130 | 250 | 260 | 330 | 500 |
Data from the manufacturer's documents, subject to change without notice — ask about the right model for your use at 086-493-5886
All In One Heat Pump Water Heater
A dual energy system combining air-to-water technology and intelligent electronic water technology
to deliver hot water in a short time and in all weather conditions.
Enjoy convenient hot water with an energy-saving design.
Operates at -15 to 70 degrees Celsius, anywhere and at any time.
Features
- Tank material : high-grade duplex stainless steel 2250/2304 options
- Control display : elegant touch screen with optional Wi-Fi function
- Fan motor : optional EC motor for higher efficiency and extra quiet operation
- High efficiency : external copper coil wrapped around the inner tank, more efficient and safer for users
- Refrigerant : environmentally friendly R410A
- Protection : advanced corrosion protection for the water tank, with optional titanium anode
Internal structure: copper coil wrapped around the outside of the tank, keeping water separate from the refrigerant
Shintaeki Heat Pump Specification
All In One Heat Pump Water Heater
| Model | HP-SHIN-300L |
|---|---|
| Rated heating capacity | 3000 W |
| Tank nominal capacity | 300 L |
| Energy efficiency class | A |
| COP A20/W55 | 3.75 |
| Rated heating current | 3.7 A |
| Heating rated power | 810 W |
| Max. input current | 6.5 A |
| Max. input power | 1100 W |
| Power supply | 220 ~ 240V / 1Ph / 50Hz |
| Compressor brand | Panasonic / Mitsubishi / GMCC |
| Refrigerant | R410A |
| Controller | LCD digital display |
| Type of defrosting | Reverse circulation |
| Expansion valve | Electronic expansion valve included |
| Fan motor | AC fan motor |
| Water tank inner tank material | Stainless steel SUS304 |
| Inner tank material thickness | 2.0 mm |
| Outer tank shell material | Galvanized steel with white or silver-grey color painting, black color ABS plastic top cover |
| Water tank insulation | PU foaming insulation |
| Water tank insulation thickness | 45–50 mm |
| Heat pump heat exchanger coil | Outside wrapping |
| Auxiliary electrical heating | 3 kW / 220~240V / 50Hz |
| Mg. anode | G3/4" female, Ø22 × 300 mm |
| Water drain connection | Male G1/2 |
| Max. water temperature | 70 °C |
| Rated water temperature | 55 °C |
| Max. working pressure of tank | 1.0 MPa |
| Rated water pressure | 0.6 MPa |
| Set point relief valve | 0.7 MPa |
| Working ambient temperature | 0 °C ~ 43 °C |
| Water-proof resistance class | IPX0 |
| Hot water supply (L/h, 15 °C → 55 °C) | 134 L/h |
| Sound pressure level | < 50 dB(A) |
| Net weight | 85 kg |
| Net dimensions | 640 × 1780 mm |
Ask About the Right Model and Size
for Your Building
Tel 086-493-5886 , 089-497-9681
Our engineers will help you choose a model and estimate your initial savings